§ 15.36.010. Fire Code.¶
California Code of Regulations Title 24, Part 9: 2025 California Fire Code including Appendix Chapter 4 (Special Detailed Requirements Based on Use and Occupancy), Appendices B and BB (Fire Flow Requirements for Buildings), Appendices C and CC (Fire Hydrant Locations and Distribution), Appendix D (Fire Apparatus Access Roads), Appendix E (Hazard Categories), Appendix F (Hazard Ranking), Appendix G (Cryogenic Fluids – Weight and Volume Equivalents), Appendix H (Hazardous Materials Management Plans and Hazardous Inventory Statements), Appendix I (Fire Protection Systems – Noncompliant Conditions), Appendix J (Building Information Sign), Appendix K (Construction Requirements for Existing Ambulatory Care Facilities), Appendix L (Requirements for Fire Fighter Air Replenishment Systems), Appendix N (Indoor Trade Shows and Exhibitions), and Appendix P (Temporary Haunted Houses, Ghost Walks and Similar Amusement Uses), referred to as the "International Fire Code" or "IFC," is adopted with the following amendments and made a part of this Title by reference.
(Ord. 779, 11/18/2025)
§ 15.36.020. Definitions.¶
For the purposes of this Chapter, wherever the phrase "new construction" is used in the California Fire Code, it shall be defined as: "any work, including but not limited to, an addition, remodel, repair, renovation, or alteration of any building or structure."
Substantial Remodel.
"Substantial remodel" shall mean the alteration of any structure which combined with any additions to the structure, performed within any three year period, affects a floor area which exceeds 50% of the existing floor area of the structure. When any changes are made in the building, such as walls, columns, beams or girders, floor or ceiling joists and coverings, roof rafters, roof diaphragms, foundations, piles or retaining walls or similar components, the floor area of all rooms affected by such changes shall be included in computing floor areas for purposes of applying this definition. This definition does not apply to the replacement and upgrading of residential roof coverings or exterior wall finishes.
(Ord. 779, 11/18/2025)
§ 15.36.030. Amendments.¶
The California Fire Code is amended as follows.
A. A. Division II Administration
California Fire Code Section 101.1 is added to read as follows:
101.1 Title. These regulations shall be known as the Fire Code of the City of Calistoga, hereinafter referred to as "this code."
California Fire Code Section 103.1 is amended to read as follows:
103.1 Creation of Agency. The Calistoga Fire Department is hereby created and the official in charge thereof shall be known as the fire code official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code.
California Fire Code Section 104.10.1 is added to read as follows:
104.10.1.1 Fire Prevention Bureau Personnel and Police. All sworn safety personnel assigned to the Fire and Life Safety Division, or such other full-time Fire Department officers or fire prevention personnel as may be authorized by the Chief, shall be peace officers as described in California Penal Code Section 830.37 and shall enforce the Penal Code, California Fire Code, and where necessary and appropriate, any sections of the Calistoga Municipal Code, California Health and Safety Code, and any other county or state fire-related laws or codes not specifically covered in any part of this Code. These police powers include the issuance of misdemeanor citations (Notice to Appear), and as approved by the Chief, carrying and use of firearms.
When requested to do so by the Fire Chief, the Chief of Police is authorized to assign such available police officers as necessary to assist the Fire Department in enforcing the provisions of this Code.
California Fire Code Section 105.2.5 is added to read as follows:
105.2.5 - Inspection and permit Fees. The Fire Chief may establish a schedule of fees, as approved by the City Council, to be charged and collected for completing required inspection services and for the issuance of permits pursuant to Section 105.7 of this Code. Fire service fees may be charged to any person, firm, corporation or business that through negligence, violation of the law or as a result of carelessness is responsible for the cause of any fire department response to the scene of such an incident. A copy of fee schedules shall be kept in the office of the City Clerk and the office of the Fire Chief and shall be available for public inspection.
California Fire Code Section 105.5 is amended to read as follows:
105.5 Required Operational Permits. The fire code official is authorized to issue operational permits for operations set forth in Sections 105.5.2.1 through 105.5.58.
California Fire Code Section 105.5.59 is amended as follows:
105.5.59 Additional permits. In addition to the permits required by Section 105.6, the following permits shall be obtained from the Bureau of Fire Prevention prior to engaging in the following activities, operations, practices or functions:
| 1. | Production facilities. To change use or occupancy, or allow the attendance of a live audience, or for wrap parties. |
|---|---|
| 2. | Pyrotechnics and special effects. To use pyrotechnic special effects, open flame, use of flammable or combustible liquids and gases, welding and the parking of motor vehicles in any building or location used for the purpose of motion picture, television and commercial production. |
| 3. | Live audiences. To install seating arrangements for live audiences in approved production facilities, production studios and sound stages. See Chapter 48. |
| 4. | Apartment house, hotel, or motel. An operational permit is required to operate an apartment house, hotel or motel. |
| 5. | Care facilities. An operational permit is required to operate a care facility as listed: |
| a. | Day care with an occupant load greater than six (6) persons. |
| b. | Residential or commercial institutional care facility. Occupancies complying with Health and Safety Code Section 13235 are exempt. |
| 6. | Emergency Responder Radio System. An operational permit is required to operate an Emergency Responder Radio System. |
| 7. | High rise occupancy. An operational permit is required to operate a high rise building as defined in California Code of Regulations Title 24 , Part 2. |
| 8 | Model rockets rental, sale or operation. An operational permit is required to operate, manufacture, import, export, possess, store, rent or sell model rockets as defined by Health and Safety Code Section 12519 . |
| 9. | Agricultural burning. |
California Fire Code Section 113.3.5 is added as follows:
113.3.5 Authority to issue citations. The Fire Code Official is authorized to issue a citation to persons operating or maintaining an occupancy, premise, or vehicle subject to this code, who allows a hazard to exist or fail to take immediate action to abate a hazard on such occupancy, premises, or vehicle when ordered or notified to do so.
California Fire Code Section 113.3.6 is added as follows:
113.3.6 Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be subject to a penalty as prescribed in CMC Chapter 1.08.
California Fire Code Section 113.4 is amended to read as follows:
1.08 Violation penalties. In accordance with the provisions of CMC Chapter 1.08 and this code, any persons who violate a provision of this code or fail to comply with any of the requirements thereof or who erect, install, alter, repair, or do work in violation of the approved construction documents or directive of the fire code official, or of a permit or certification used under provisions of this code, or any person operating or maintaining any occupancy, premises, or vehicle subject to this code, fire and life safety provisions of the California Building Code, or allow any fire hazard to exist on premises under their control or who fail to take immediate action to abate a fire hazard when ordered or notified to do so by the fire code official or authorized designee shall be subject to CMC Chapter 1.08. The imposition of one penalty of any violation shall not excuse the violation or permit it to continue. All such persons shall be required to correct or remedy such violations or defects within a reasonable time. When not otherwise specified, each day that a violation continues after due notice has been served shall be deemed a separate offense.
B. CHAPTER 2 DEFINITIONS
California Fire Code Section 201.5 is added as follows:
Section 201.5 Wherever the word "jurisdiction" is used in the 2022 California Fire Code and 2015 International Fire Code, it shall be understood to mean that the City of Calistoga is the local fire authority having jurisdiction (AHJ).
California Fire Code Section 202 is amended as follows:
TENT. A structure, enclosure, umbrella structure or shelter with or without sidewalls or drops, constructed of fabric or pliable material supported by any manner except by air or the contents that it protects.
The following are added to California Fire Code Section 202, General Definitions:
WEEDS. Vegetation which when mature bear wingy or downy seeds, or which because of having attained, or which may attain, such a large growth and being dry shall have become a fire menace, or which are otherwise noxious and dangerous to health.
C. CHAPTER 3 GENERAL PRECAUTIONS
California Fire Code Section 304.1.3.1 and 304.1.3.1.1 are added as follows:
304.1.3.1 Vegetation on non-developed parcel. Any non-developed parcel shall maintain vegetation in such manner as to reduce the potential for the ignition and/or spread of fire. 304.1.3.1.1 Vegetation management on non-developed parcel. Every property owner shall remove or destroy such weeds and/or debris on their property, on all sides of their property, including those sides next to, adjoining, or having commonality with public property, and on the abutting half of the street in front of, and alleys behind, if any, such property.
California Fire Code Section 307.1.1 is amended as follows:
Section 307.1.1 Prohibited open burning. Open burning within the city limits of Calistoga, including incinerators of all types, is prohibited.
Exceptions:
| 1. | Agricultural burning permitted by the City of Calistoga Fire Department and regulated by the Bay Area Air Quality Management District. |
|---|---|
| 2. | Barbecues used for cooking purposes, provided the barbecues shall not be used for burning rubbish, paper, boxes, grass, brush or other combustible items, except charcoal, natural gas or other materials commonly used in barbecues for cooking purposes. |
California Fire Code Section 307.1.2 is added as follows:
307.1.2 Prohibitions on Disposal and Burning Fires.
| A. | No person shall deposit any ashes, coals, charcoal, or other fire debris in a container that is combustible or may be compromised by heat, or on the floor of any building or within ten (10) feet of any woodwork or structure, unless secured in a metallic vessel. | No person shall deposit any ashes, coals, charcoal, or other fire debris in a container that is combustible or may be compromised by heat, or on the floor of any building or within ten (10) feet of any woodwork or structure, unless secured in a metallic vessel. |
|---|---|---|
| B. | No person shall deposit or throw into or on any street, sidewalk, alley or public place any paper, ashes, filth, dirt or trash of any kind. | No person shall deposit or throw into or on any street, sidewalk, alley or public place any paper, ashes, filth, dirt or trash of any kind. |
| C. | No person shall bury any garbage, rubbish, recyclable, waste material, or refuse matter. | No person shall bury any garbage, rubbish, recyclable, waste material, or refuse matter. |
| D. | No person shall burn any garbage, rubbish, recyclable, waste material, refuse matter or substance, except as expressly authorized below: | No person shall burn any garbage, rubbish, recyclable, waste material, refuse matter or substance, except as expressly authorized below: |
| 1. | Burns authorized by this Section shall conform to Bay Area Air Quality Management District (BAAQMD) Regulation #5, "Open Burning", as the same may be amended from time to time, provided the burn occurs during a BAAQMD North Zone declared permissive burn day. | |
| 2. | Any and all burns shall require a burning permit issued by the Calistoga Fire Department ("Burn Permit") prior to ignition. A Burn Permit shall constitute an operational permit under Section 105 of the California Fire Code, as amended by the Calistoga Municipal Code and shall be applied for, issued, maintained, and subject to suspension or revocation in accordance with Section 106 of the California Fire Code, as amended by the Calistoga Municipal Code. Every Burn Permit shall, at a minimum, require that burning occur only between 8:00 a.m. and 5:00 p.m. | |
| 3. | Agricultural burns for the purpose of initiating, continuing or maintaining agriculture as a gainful occupation. Fuels must be limited to materials grown on the site. | |
| 4. | Only nonagricultural burns as described and defined in BAAQMD Regulation #5, Sections 5-401.1, 5-401.6, 5-401.7, 5-401.10, 5-401.14, 5-401.15 and 5-401.16, as those provisions may be amended from time to time. | |
| E. | Burn Permits may be suspended or revoked by the Fire Chief or their designee if it is determined that burning poses an increased hazard to public health or safety or if the permittee violates any condition of the permit, this Code, the Fire Code, or applicable state or regional air-quality regulations. | Burn Permits may be suspended or revoked by the Fire Chief or their designee if it is determined that burning poses an increased hazard to public health or safety or if the permittee violates any condition of the permit, this Code, the Fire Code, or applicable state or regional air-quality regulations. |
| F. | In addition to any requirements, all Burns must comply with the following: | In addition to any requirements, all Burns must comply with the following: |
| 1. | Burns must maintain a minimum clearance of thirty (30) feet from combustibles, | |
| 2. | Burns must have an adult in attendance at all times, and | |
| 3. | Prior to any burn, Burn Permit holders must notify both City Police Department dispatch and Fire Department dispatch prior to any burning. | |
| G. | In the event any burn escapes control and the City determines that the cause was due to: negligent actions before or during the burn, the failure to receive a Burn Permit, or the failure to comply with any issued Burn Permit, the applicant shall be liable for all suppression costs incurred. | In the event any burn escapes control and the City determines that the cause was due to: negligent actions before or during the burn, the failure to receive a Burn Permit, or the failure to comply with any issued Burn Permit, the applicant shall be liable for all suppression costs incurred. |
California Fire Code Section 308.1.6.3 is added as follows:
308.1.6.3 Sky Lanterns. Sky lanterns within the city limits of Calistoga are prohibited.
D. CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS
California Fire Code Section 401.3.2.1 is added as follows:
401.3.2.1 Unwarranted alarm notification. Notification of emergency responders based on an unwarranted alarm may be punishable by a fine in accordance with the adopted fee schedule. In addition, the responsible party may be liable for the operational and administrative costs incurred from the emergency response or mitigation procedures resulting from an unwarranted alarm notification.
E. CHAPTER 5 FIRE SERVICE FEATURES
California Fire Code Section 503.2.7 is amended as follows:
503.2.7 Grade. A fire department access road having a grade of between 12% and 15% shall be designed to have a finished surface of grooved concrete to hold a 74,000-pound traction load. Design for grooved concrete shall be 1/4 inch (6 mm) wide by 1/4 inch (6 mm) deep and 3/4 inch (19 mm) on center. Grades exceeding 15% are not permitted.
Exception: Other approved all weather surfaces may be used if the skid resistance is equivalent to or greater than grooved concrete as certified by a registered engineer and approved by the Fire Code Official.
California Fire Code Section 505.1 is amended as follows:
505.1 Address identification. New and existing buildings shall be provided with approved illuminated address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numerals or alphabetic letters. Numbers shall not be spelled out. Character size and stroke shall be in accordance with Sections 505.1.1 through 505.1.2. Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response in accordance with this code and Section 505.1.3. Where access is by means of a private road and the building cannot be viewed from the public way or when determined by the fire code official, a monument, pole, illuminated sign or other means shall be used to identify the structure. Address identification shall be maintained.
California Fire Code Section 505.1.1 is added as follows:
505.1.1 Numbers for one- and two-family dwellings. Each address identification character shall be not less than four (4) inches high with a minimum stroke width of one-half (0.5) inch.
California Fire Code Section 505.1.2 is added as follows:
505.1.2 Numbers for other than one- and two-family dwellings. Each address identification character shall be not less than twelve (12) inches high with a minimum stroke width of one (1) inch. Suite and unit directional numbers shall be not less than six (6) inches high with a minimum stroke width of three-quarter (0.75) inch.
California Fire Code Section 505.1.3 is added as follows:
505.1.3 Complex directory. Where two or more buildings cannot be viewed from the public way or when determined by the fire code official, an illuminated complex directory, monument, pole, sign or other approved means shall be used to identify the structures at the main entrances to the property.
California Fire Code Section 507.5.1.1 is amended as follows:
507.5.1.1 Hydrant for fire department connections. Buildings equipped with a water-based fire protection system installed in accordance with Sections 903 through 905 shall have a fire hydrant within 50 feet of the fire department connections, or as approved by the fire code official. (Also see Section 912.2).
California Fire Code Section 510.1 exception #1 is deleted.
F. CHAPTER 9 FIRE PROTECTION SYSTEMS
California Fire Code Section 903.2 is amended as follows:
903.2 Where required. Approved automatic sprinkler systems shall be provided in the locations described in Sections 903.2.1 through 903.2.21 and in items 1-5 below:
| 1. | Newly constructed buildings or facilities, except detached Group U occupancies not more than one thousand (1,000) square feet in floor area and provided with exterior wall & opening protection as per Table 602 of the California Building Code. |
|---|---|
| 2. | Newly created, attached, accessory dwelling units which meet the definition of a substantial remodel. |
| 3. | All other existing buildings, fire sprinkler systems may be required by the fire chief in accordance with the following: |
| 3.1 | All buildings where improvements occur during any three (3) year period which cumulatively meet the definition of a substantial remodel. |
| 3.2. | All buildings, except R-3 occupancies, in excess of three thousand (3,000) square feet which have more than ten percent (10%) floor area added within any three (3) year period. Exceptions may be granted by the fire chief when alternate means of protection are installed as approved by the fire code official. |
| 3.3. | A change in the use of a building that results in a higher fire or life safety hazard when the square footage of the area changing use is more than 50% of the square footage of the existing building. |
| 3.4. | Where fire sprinklers are required by provisions of this code, they shall be extended throughout the building. |
| 4. | All public storage facilities. Exceptions may be granted by the fire chief when alternate means of protection are installed as approved by the fire code official. |
| 5. | All tunnels used for the transportation of people or any type of vehicle. The requirements for fire sprinkler systems in this code section are not meant to disallow the provisions for area increase, height increase, or fire-resistive-rated substitution if otherwise allowed by this code. |
Exceptions:
| 1. | Agricultural buildings as approved by the Fire Code Official. |
|---|---|
| 2. | Detached pool houses accessory to Group R-3 not classified as a dwelling unit and not exceeding 1,000 square feet (9.28 m2) in gross floor area within 50 feet of the pool and limited to a single bathroom. |
| 3. | Detached non-combustible motor vehicle fuel dispensing canopies. |
California Fire Code Section 903.2.1 is amended to read as follows:
903.2.1 Group A. An automatic sprinkler system shall be provided throughout buildings containing a Group A occupancy.
California Fire Code Sections 903.2.1.1 through 903.2.1.5 and Section 903.2.1.7 are deleted.
California Fire Code Section 903.2.1.6 is renumbered and amended as follows:
903.2.1.6 Assembly occupancies on roofs. Where an occupied roof has an assembly occupancy with an occupant load exceeding 100 for Group A-2 and 300 for other Group A Occupancies, an automatic sprinkler system shall be provided throughout the building in accordance with Section 903.3.1.1 or 903.3.1.2.
California Fire Code Section 903.2.2 is amended to read as follows:
903.2.2 Ambulatory care facilities. An automatic sprinkler system shall be installed throughout buildings containing an ambulatory care facility.
California Fire Code Section 903.2.3 is amended to read as follows:
903.2.3 Group E. An automatic sprinkler system shall be installed throughout buildings containing a Group E occupancy.
California Fire Code Section 903.2.4 is amended to read as follows:
903.2.4 Group F. An automatic sprinkler system shall be provided throughout buildings containing a Group F occupancy.
California Fire Code Section 903.2.4.1 through 903.2.4.3 are deleted.
California Fire Code Section 903.2.5 is amended to read as follows:
903.2.5 Group H. An automatic sprinkler system shall be installed throughout buildings containing a Group H occupancy.
California Fire Code Section 903.2.7 is amended as follows:
903.2.7 Group M. An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy where gross floor area exceeds 500 square feet (4.64 m2).
California Fire Code Section 903.2.9 is amended to read as follows:
903.2.9 Group S. An automatic sprinkler system shall be provided throughout all buildings containing a Group S occupancy.
California Fire Code Sections 903.2.9.1 through 903.2.9.4 are deleted.
California Fire Code Section 903.2.10 is amended to read as follows:
903.2.10 Group S2 parking garages. An automatic sprinkler system shall be provided throughout all buildings containing a Group S2 occupancy.
California Fire Code Section 903.2.10.1 through 903.2.10.2 are deleted.
California Fire Code Section 903.2.11 is amended as follows:
903.2.11 Specific buildings areas and hazards. In all occupancies other than detached Group U occupancies not greater than 1,000 square feet (92.8 m2), an automatic sprinkler system shall be installed for building design or hazards in the locations set forth in Sections 903.2.11.1 through 903.2.11.8.
California Fire Code Section 903.2.11.3 exception is deleted. California Fire Code Section 903.2.11.7 is added as follows:
903.2.11.7 Undetermined use design. Automatic sprinkler systems installed in buildings or structures of undetermined use shall be designed and installed to have a minimum density of .33 gallons per minute per square foot over a minimum design area of 3,000 square feet (278.7 m2).
California Fire Code Section 903.2.11.8 is added as follows:
903.2.11.8 High-piled storage. An automatic sprinkler system shall be provided throughout as required in California Fire Code Chapter 32 in all buildings where storage is in high-pile or rack storage arrays.
California Fire Code Section 903.2.22 is added as follows:
903.2.22 Alterations or Repairs. For alterations or repairs that qualify as a substantial remodel, the building shall meet the fire sprinkler requirements for a newly-constructed building. See definition of Substantial Remodel (Section 15.12.015).
Exceptions to this Section:
One-time alterations made solely for the purpose of complying with the Americans with Disabilities Act.
Work associated with the creation of an accessory dwelling unit or junior accessory dwelling unit, as defined by Govt. Code 65852.2 and 65852.22,[1] if fire sprinklers are not required for the primary residence.
California Fire Code Section 903.2.23 is added as follows:
903.2.23 Change in Occupancy. For any change of occupancy when the proposed new occupancy classification is more hazardous based on a fire and life safety evaluation by the fire code official and building code official, including conversions of buildings to single-family residences, accessory dwelling units, bed and breakfasts, inns, lodging houses or congregate residences for 10 or fewer persons or other similar uses, an automatic fire sprinkler shall be installed throughout.
California Fire Code Section 903.4.2 is amended as follows:
903.4.2 Alarms. One exterior approved audible and visual device, located on the exterior of the building in an approved location, shall be connected to each automatic sprinkler system. Such sprinkler water-flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system.
California Fire Code Section 905.3.1 item #2 is amended as follows:
905.3.1. (2) Buildings that are three or more stories in height. California Fire Code Section 905.9 exception #2 is deleted. California Fire Code Section 912.2 is amended as follows: 912.2 Location. With respect to hydrants, driveways, buildings and landscaping, fire department connections shall be so located that fire apparatus and hose connected to supply the system will not obstruct access to the buildings for other fire apparatus. The location of fire department connections shall be approved by the fire code official (Also see Section 507.5.1.1).
[1]
Editor's Note: See now Government Code Section 66313.
G. CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION
California Fire Code Section 3315.3 is added as follows:
3315.3 Where required. In buildings of combustible construction required to have automatic sprinkler system by Section 903, automatic sprinkler system shall be installed prior to construction exceeding 40 feet (12.192 meters) in height above the lowest level of fire department vehicle access. Such automatic sprinkler system shall be extended as construction progresses to within one floor of the highest point of construction having secured decking or flooring.
California Fire Code Section 3315.4 is added as follows:
3315.4 Buildings being demolished. Where a building is being demolished and an automatic sprinkler system exists within such a building, such automatic sprinkler system shall be maintained in an operable condition so as to be available for use by the fire department. Such automatic sprinkler system shall be demolished with the building but shall not be demolished more than one floor below the floor being demolished.
H. CHAPTER 56 EXPLOSIVES AND FIREWORKS
California Fire Code Section 5601.1.6 is added as follows:
5601.1.6 Sale, use or discharge of fireworks prohibited - exception. Except for firework displays authorized pursuant to this section, it is unlawful for any person to possess, store, offer or expose for sale, sell at retail, give away or in any manner dispose of any fireworks, or to use, explode, or otherwise discharge any fireworks. California Fire Code Section 5601.2.5 is added as follows:
Section 5601.2.5 Limits Established by Law.
The limits referred to in Chapter 56 of the California Fire Code, in which storage of explosives and blasting agents is prohibited, are hereby established as follows: Storage is prohibited in all areas of the City unless a permit is issued by the fire code official.
I. CHAPTER 57 FLAMMABLE AND COMBUSTIBLE LIQUIDS
California Fire Code Section 5701.6 is added as follows:
5701.6 Establishment of Limits
Establishment of Limits of Districts in which the Storage of Hazardous Materials is prohibited: The limits referred to in Chapter 50 of the California Fire Code in which the storage of hazardous materials is prohibited, are hereby established as follows: Storage is prohibited in all areas of the City unless a permit is issued by the Fire Code Official. Establishment of Limits of Districts in which the Storage of Compressed Gases is Prohibited: The limits referred to in Chapter 53 of the California Fire Code in which the storage of compressed gases is prohibited, are hereby established as follows: Storage of 16 gallons or more is prohibited in all areas of the City unless a permit is issued by the Fire Code Official.
Establishment of Limits of Districts in which Storage of Explosives and Blasting Agents is Prohibited: The limits referred to in Chapter 56 of the California Fire Code, in which storage of explosives and blasting agents is prohibited, are hereby established as follows: Storage is prohibited in all areas of the City, unless a permit is issued by the Fire Code Official.
Establishment of Limits of Districts in which Storage of Flammable or Combustible Liquids in Outside Above-ground Tanks is Prohibited: The limits referred to in Chapter 57 of the California Fire Code, in which the storage of flammable or combustible liquids in outside above-ground tanks is restricted, are hereby established as follows: Storage of 16 gallons or more is prohibited in all areas unless a permit is issued by the Fire Code Official.
Establishment of Limits of Districts in which Storage of Liquefied Petroleum Gas is prohibited: The limits referred to in Chapter 57 of the California Fire Code, in which storage of liquefied petroleum gas is prohibited, are hereby established as follows: Storage is prohibited in all areas of the City unless a permit is issued by the Fire Code Official.
Establishment of Limits of Districts in which the Storage of Stationary Tanks of Flammable Cryogenic Fluids is Prohibited: The limits referred to in Chapter 58 of the California Fire Code in which the storage of flammable cryogenic fluids in stationary containers is prohibited, are hereby established as follows: Storage is prohibited in all areas of the City unless a permit is issued by the Fire Code Official.
California Fire Code Section 5706.2.4.5 is added as follows:
Section 5706.2.4.5 Establishment of Limits of Districts in which Storage of Liquefied Petroleum Gases is prohibited. The limits referred to in Chapter 57 of the California Fire Code, in which storage of liquefied petroleum gas is prohibited, are hereby established as follows: Storage is prohibited in all areas of the city unless a permit is issued by the fire code official.
J. CHAPTER 61 LIQUEFIED PETROLEUM GASES
California Fire Code Section 6104.2 is amended as follows:
Section 6104.2 Maximum capacity within established limits.
Within the limits established by law restricting the storage of liquefied petroleum gas for the protection of heavily populated or congested areas, the aggregate capacity of any one installation shall not exceed a water capacity of 500 gallons (1893 L).
K. Appendix C Fire Hydrant Locations and Distribution
California Fire Code Appendix C102 is amended by adding the following appendix: C102.2 Fire Department Connections. A fire hydrant shall be located within 50 feet of all Fire Department Connections (FDC), or as approved by the fire code official.
L. Appendix D Fire Apparatus Access Roads
California Fire Code Appendix D107.1 is amended as follows:
D107.1 One- or two-family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 20 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Appendix D104.3.
Exceptions 1 and 2 are deleted.