Bakersfield Municipal Code § 17.12.030 Mixed-use zone development standards
Bakersfield Municipal Code · 2026-09 edition · updated 2026-10-02 · Bakersfield
Cite as: Bakersfield Municipal Code § 17.12.030 · Text as of 2026-10-02
17.12.010 Purposes of mixed-use zones.¶
A. Purpose. The purpose of this chapter is to describe the character and intent of the city’s mixed-use zones, describe allowed land uses and permit requirements in mixed-use zones, identify any supplemental land use regulations applicable to mixed-use zones, and establish development standards for the same.
B. Zoning Map. The boundaries, designations, and locations of the zones established by this zoning code shall be shown upon the map(s) entitled “Zoning Map for City of Bakersfield” and referred to in this zoning code as the zoning map. Any additional maps adopted shall also be a part of this zoning code by reference. This zoning code, together with the zoning map, is hereby adopted in compliance with current state planning, zoning, and development laws.
C. Zone Purpose Statements. The purpose of the individual mixed-use uses and the way they are applied are as follows:
MX-1 (Mixed-Use Neighborhood) Zone. The purpose of the MX-1 mixed-use neighborhood zone is to provide areas within the city for pedestrian oriented developments that focus on neighborhood-serving commercial uses (e.g., coffee shops, grocery stores, retail establishments). This zone also allows mixed-use development comprised of medium-density multi-unit developments (i.e., cottage court apartments, low-rise apartments, and condominiums), It is the intent of the MX-1 zone to encourage a mix of residential and commercial uses, with residential on the upper floors and commercial on the lower floors (vertical mixed-use format), as well as, stand-alone uses in certain circumstances (horizontal mixed-use format). The residential density range for this zone is twenty to thirty dwelling units per acre.
MX-2 (Mixed-Use Transit) Zone. The purpose of the MX-2 mixed-use transit zone is to provide for transit- and pedestrian-oriented mixed-use development comprised of high density multi-unit developments (i.e., low-rise, mid-rise apartments, and condominiums). The focus of such development will be on centralized urban development along major corridors, interchanges, transit hubs, and throughout downtown Bakersfield, in conjunction with existing and planned transit facilities to support and maximize transit use. This zone is intended to encourage high quality integrated development consisting of residential and commercial uses in a horizontal and/or vertical arrangement to maximize open space of active and passive use and provide opportunities for place making. The residential density range for this zone is 30.1 to one hundred dwelling units per acre. (Ord. 5155 § 2, 2024)
17.12.020 Mixed-use land use regulations and allowable uses.¶
A. Mixed-Use Zones Allowed Uses and Permit Requirements. Table 17.12-1 indicates the uses allowed within each mixed-use zone and any permits required to establish the use, in compliance with Chapter 17.08, General Regulations Including Site Plan Review.
B. Additional Regulations. Where the last column in Table 17.12-1 includes a chapter or section number, the regulations in the referenced chapter or section shall apply to the use. Provisions in other sections of this zoning code, municipal code, and state law may also apply.
C. Definitions. See Chapter 17.04, Definitions, for land use definitions and explanations.
D. Uses Not Listed. Uses not listed below may be reviewed by the planning director to determine if they are similar to those listed and appropriate in this zone and if so, what type of permit is required.
= and CUP 1502 1502 50801(e) 65582(d) Section Section Section Regulations Allowed; Sections Code Code Section Code Not = N Code Safety Safety Code Safety Additional and and and Approval; 17.65 17.12.040 17.04.160 Government 1597.30—1597.622 17.04.154.50 Health 17.04.154.50 Health Government Health Requirements and Permit Review and Zone MX-2 P P CUP P CUP P P P by Uses Director = DRA Allowed Permit Right; Requirement Zones by Use
P P P P P P CUP CUP Permit MX-1
Mixed-Use Allowed= P Conditional
17.12-1.
or seven attached, to Table (seven (up residents
Large Small seven Use (detached,
Key: to up Land Unit Facility, Facility, Facility Home
Uses Dwelling Structure Care Care Care Shelter Housing, Living Day residents) Residential Accessory junior) Accessory Assisted Child Community more Community residents) Emergency Employee for for with (i) when with the density and = housing sites be of right comply CUP by comply shall more lower-income designated minimum and 65660—65668 or for 65583.2(h) previous and 65583.2(c) rezoned are
on on Regulations 20% meet acre allowed Allowed; element units per Sections be Section reserved also Sections Not when = the units households Code N Code shall of Code housing are Must Additional right developments developments sites cycle by more units dwelling
or 6th Approval; 20 17.04.330 17.63 Government Housing element 20% lower-income Government Housing the allowed housing households. of Government Requirements and
Permit Review
P P N P P P Pand Zone MX-2
byUses Director
= DRA Allowed Permit Right; Requirement Zones by Use
P P P P P P CUP Permit MX-1
Mixed-Use Allowed= P Conditional 17.12-1. Table Parks or Trailer Use Center Units Sites Key: (standalone Land Parks/Travel Occupancy Navigation Dwellings Developed Home Sites Occupation Barrier Home Low Mobile Multi-Unit incorporated) Previously Rezoned Single-Room
= CUP 65651 65651 Regulations Allowed; Section Section Not = N Code Code Additional Requirements Approval;and Government Government 17.22.020 17.22.030 17.24.040 17.24.020 17.24.030 17.24.040 Permit Review
P P P n/a n/a n/a DRA CUPand Zone MX-2
byUses Director
= DRA Allowed Permit Right; Requirement Zones by Use
P P P DRA CUP n/a n/a n/a Permit MX-1
Mixed-Use Allowed= P Conditional
17.12-1. Use Use Uses¶
Uses Table Zone Planning Planning to Conditional to Conditional Zone by by Use Key: Approval Approval Commercial Subject Only Subject Only Land and and Commercial Housing Permitted Permitted Review Permitted Review Permitted Housing Neighborhood PermittedUses PermittedUses Uses Regional Uses Uses Uses Supportive Transitional C-1 C-1 C-1 Director C-1 Permit C-2 C-2 C-2 Director C-2 Permit
(Ord. 5206 § 1, 2025; Ord. 5184 § 1, 2024; Ord. 5155 § 4, 2024)
17.12.030 Mixed-use zone development standards.¶
A. Table 17.12-2, Mixed-Use Zone Development Standards. The intent of Table 17.12-2 is to clearly and precisely establish the basic site and structure regulations that apply to all developments in each of the mixed-use zones. The table also indicates where additional site and structure requirements, including, but not limited to, off-street parking, landscaping, signage, fences and obstructions, and performance standards, apply to mixed-use zones.
B. Density. Maximum density standards shall be consistent with this title, the general plan (or applicable master plan, specific plan, or area plan).
(ft.)
10/15 5/15 Rear Zone to: Zone/
ft.) Side- Corner (ft.) 5/10 0/10 (min. Adjacent Commercial Noncommercial (ft.) 5/10 5/10 Chapter Setbacks Side or
(ft.) 0 0 Section
Front Standards specified)
3 N/A Units 17.65 Feature Between Accessory otherwise Structures Development 17.08.130 ft.) 17.12.040 Chapter Section 3 Regulations N/A Zones unless Units (min. Between Dwelling/ Accessory Development between Additional Mixed-Use (minimum 10 N/A Distance Units Between Dwelling
17.12-2. ft.)¶
75 120 Height Table (max.
per
(min feet) N/A N/A Parcel square Regulation Area Dwelling
or (min Units N/A N/A Parcel square feet acres) Area Dwelling Structures
Zone MX-1 MX-2 Other Applicable Regulation Accessory Accessory
Chapter
or
Section
17.61 17.14 17.58 17.60 17.08.180 17.08.110 17.08.125 17.08.170
Section Section Chapter Chapter Chapter Section Section Chapter Regulations
Additional
Standards
Regulation Design
Loading Objective Hedges and Exceptions and Standards Buildings Dwelling Parking Walls, of Setback Encroachments Fences, Height Landscape Multi-Unit Off-Street Street Yard Signs
(Ord. 5155 § 4, 2024)
17.12.040 Other applicable regulations and standards.¶
A. MX-1-Mixed-Use Neighborhood Zone. Additional Standards per the Allowable Uses in Table 17.12-2.
1. Accessory Structures.
a. The accessory buildings or structures necessary for such use located on the same lot or parcel of
land, including a storage garage for the exclusive use of the patrons and employees of the above stores
or businesses.
2. Caretaker Unit.
a. Dwelling for use by caretaker or night security, or as accessory and incidental to the permitted use
on the parcel.
Additional Development Standards per Those in Table 17.10-2.
3. Side Setback.
a. The side and side-corner setback shall be a minimum of ten feet when the lot abuts upon the side of
a lot in any zone other than a commercial zone.
4. Rear Setback.
a. The rear setback shall be a minimum of fifteen feet when the lot abuts upon the side of a lot in any
zone other than a commercial zone. If the lot abuts a commercial zone the rear setback can be ten feet.
5. Multi-Story Step-Backs.
a. A minimum step-back of three feet is required for all structures greater than two stories on all
elevations of the structure on no less than sixty percent of the first story structure’s wall length.
6. Separation of Uses.
a. Commercial development proposed adjacent to property zoned or designated for residential
development shall be required to be separated by a solid masonry wall constructed a minimum height of
six feet from highest grade. Any wall located within or along the front yard area shall not exceed a height
of four feet.
7. Rooftop Equipment.
a. Rooftop areas of commercial structures shall be completely screened from view by parapets or
other finished architectural features constructed to a height of the highest equipment and unfinished
structural element or architectural feature of the building. This requirement shall apply to all new
commercial construction and remodeling of existing commercial structures which involve a change of
fifty percent or more of the roof structure or an addition of fifty percent or more to the floor area of the
commercial structure.
8. Encroachments.
a. An encroachment permit is required for any sidewalk uses including, but not limited to those
identified in Table 17.12-3.
Table 17.12-3. Mixed-Use Zone Setback Encroachments
Regulation Section or Chapter
Sills, eaves, cornices, canopies, and other similar architectural Allowed in setback area
features 8 feet or more above surface grade
Movable tables, chairs, umbrellas, outdoor heaters (outdoor Allowed in setback area seating) as allowed with an encroachment permit
Movable partitions or planters to define an outdoor seating Allowed in setback area
area
Bicycle racks Allowed in setback area
Trees and tree wells Allowed in setback area
Planters and planting beds extending not more than 18 inches Allowed in setback area
into the setback area and not more than 18 inches in height
above grade
Bay windows, on a foundation or cantilevered, chimneys, or Allowed in setback area
wells for basement windows or stairs, occupying in the
aggregate not more than 20 percent of the length of the side
of the structure on which they are located.
Utility structures Allowed in setback area
B. MX-2-Mixed-Use Transit Zone—Additional Development Standards per Those in Table 17.10-2.
1. Side Setback.
a. The side and side-corner setback shall be a minimum of ten feet when the lot abuts upon the side of
a lot in any zone other than a commercial zone.
2. Rear Setback.
a. The rear setback shall be a minimum of fifteen feet when the lot abuts upon the side of a lot in any
zone other than a commercial zone. If the lot abuts a commercial zone the rear setback can be five feet.
(Ord. 5155 § 4, 2024)