Chapter IXArticle 9

§ 99.04

Los Angeles Rent Rules (LAMC excerpts) · edición 2025 · actualizado 2026-07-08 · Los Angeles

SEC. 99.04.100. BASIC PROVISIONS.

Esta sección aún no está traducida y se muestra en inglés.

(Amended by Ord. No. 187,719, Eff. 1/23/23.)

Chapter 4 of the California Green Building Standards Code is adopted by reference except as amended herein.

SEC. 99.04.106.

(Amended by Ord. No. 186,488, Eff. 12/27/19.)

99.04.106.2. Storm Water Drainage and Retention During Construction. Projects which disturb soil shall manage storm water drainage during construction. In order to manage storm water drainage during construction one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site:

  1. Retention basins of sufficient size shall be utilized to retain storm water on the site;

  2. Where storm water is conveyed to a public drainage system, collection point, gutter, or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the Department; or

  3. Compliance with City of Los Angeles’ storm water management ordinance (s).

99.04.106.4.2. New Multi-family Dwellings, Hotels and Motels and New Residential Parking Facilities. (Amended by Ord. No. 187,719, Eff. 1/23/23.) When parking is provided, parking spaces for new multi-family dwellings, hotels and motels shall meet the requirements of Sections 99.04.106.4.2.1 and 99.04.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A parking space served by electric vehicle supply equipment or designed as a future EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details.

99.04.106.4.2.1. Multi-family Development Projects with less than 20 Dwelling Units; and Hotels and Motels with less than 20 Sleeping Units or Guest Rooms. (Added by Ord. No. 187,719, Eff. 1/23/23.) The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section.

  1. EV Capable. Thirty percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer (s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces. An automatic load management system (ALMS) may be used to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes.

The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as "EV CAPABLE" in accordance with the California Electrical Code.

EXCEPTIONS:

  1. When EV chargers (Level 2 EVSE) are installed in a number equal to or greater than the required number of EV capable spaces.

  2. When EV chargers (Level 2 EVSE) are installed in a number less than the required number of EV capable spaces, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed.

NOTES:

a. Construction documents are intended to demonstrate the project's capability and capacity for facilitating future EV charging and shall show locations of proposed EV spaces.

b. There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use.

  1. EV Ready. Twenty-five percent of the total number of parking spaces, but in no case less than one per multi-family dwelling unit, shall be equipped with low power Level 2 EV charging receptacles. For multi-family dwelling parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. The number of EV Ready parking spaces may be counted toward the total number of EV Capable parking spaces required for the building per Los Angeles Municipal Code Subsection 99.04.106.4.2.1, Item 1.

EXCEPTION: Areas of parking facilities served by parking lifts.

99.04.106.4.2.2. Multi-family Development Projects with 20 or More Dwelling Units, Hotels and Motels with 20 or More Sleeping Units or Guest Rooms. (Added by Ord. No. 187,719, Eff. 1/23/23.) The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section.

  1. EV Capable. Thirty percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces. An automatic load management system (ALMS) may be used to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes.

The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as "EV CAPABLE" in accordance with the California Electrical Code.

EXCEPTION: When EV chargers (Level 2 EVSE) are installed in a number greater than five (5) percent of parking spaces required by Los Angeles Municipal Code Subsection 99.04.106.4.2.2, Item 3, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed over the five (5) percent required.

NOTES:

a. Construction documents are intended to demonstrate the project's capability and capacity for facilitating future EV charging and shall show locations of proposed EV spaces.

b. There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use.

  1. EV Ready. Twenty-five percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. For multi- family dwelling parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. The number of EV Ready parking spaces may be counted toward the total number of EV Capable parking spaces required for the building per Los Angeles Municipal Code Subsection 99.04.106.4.2.2, Item 1.

EXCEPTION: Areas of parking facilities served by parking lifts.

  1. EV Chargers. Ten percent of the total number of parking spaces shall be equipped with Level 2 EVSE. Where common use parking is provided, at least one EV charger shall be located in the common use parking area and shall be available for use by all residents or guests.

When low power Level 2 EV charging receptacles or Level 2 EVSE are installed beyond the minimum required, an automatic load management system (ALMS) may be used to reduce the maximum required electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes and installed EVSE shall have a capacity of not less than 30 amperes. ALMS shall not be used to reduce the minimum required electrical capacity to the required EV capable spaces.

99.04.106.4.2.2.1. Electric Vehicle Charging Stations (EVCS). (Added by Ord. No. 187,719, Eff. 1/23/23.) Electric vehicle charging stations required by Los Angeles Municipal Code Subsection 99.04.106.4.2.1, Item 3, or LAMC Subsection 99.04.106.4.2.2, Item 3, shall comply with Los Angeles Municipal Code Subsection 99.04.106.4.2.3.

EXCEPTION: Electric vehicle charging stations serving public accommodations, public housing, motels, and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements.

99.04.106.4.2.2.1.1. Location. (Amended by Ord. No. 188,739, Eff. 9/23/25.) EVCS shall comply with at least one of the following options:

  1. The charging space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space.

  2. The charging space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building.

EXCEPTION: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with LAMC Subsections 99.04.106.4.2.2.1.1, and 99.04.106.4.2.2.1.2, Item 3.

99.04.106.4.2.2.1.2. Electric Vehicle Charging Stations (EVCS) Dimensions. (Added by Ord. No. 187,719, Eff. 1/23/23.) The charging spaces shall be designed to comply with the following:

  1. The minimum length of each EV space shall be 18 feet (5486 mm).

  2. The minimum width of each EV space shall be 9 feet (2743 mm).

  3. One in every 25 charging spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EV space is 12 feet (3658 mm).

a. Surface slope for this EV space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction.

99.04.106.4.2.2.1.3. Accessible EV Spaces. (Added by Ord. No. 187,719, Eff. 1/ 23/23.) In addition to the requirements in Sections 4.106.4.2.3.1 and 4.106.4.2.3.2, all EVSE, when installed, shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and EVCS in multi-family developments shall comply with California Building Code, Chapter 11A, Section 1109A.

99.04.106.4.2.3. EV Space Requirements. (Added by Ord. No. 187,719, Eff. 1/23/ 23.)

  1. Single EV Space Required. Install a listed raceway capable of accommodating a 208/240-volt dedicated branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or enclosure in close proximity to the location or the proposed location of the EV space. Construction documents shall identify the raceway termination point, receptacle or charger location, as applicable. The service panel and/or subpanel shall have a 40-ampere minimum dedicated branch circuit for EV chargers or a 20-ampere minimum dedicated branch circuit for EV Ready parking spaces, including branch circuit overcurrent protective device installed, or space(s) reserved to permit installation of a branch circuit overcurrent protective device.

EXCEPTION: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space, at the time of original construction in accordance with the California Electrical Code.

  1. Multiple EV Spaces Required. Construction documents shall indicate the raceway termination point and the location of installed or future EV spaces, receptacles, or EV chargers. Construction documents shall also provide information on amperage of installed or future receptacles or EVSE, raceway method(s), wiring schematics and electrical load calculations. Plan design shall be based upon a 40-ampere minimum branch circuit. Required raceways and related components that are planned to be installed underground, enclosed, inaccessible, or in concealed areas and spaces shall be installed at the time of original construction.

EXCEPTION: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space at the time of original construction in accordance with the California Electrical Code.

99.04.106.4.2.4. Identification. (Added by Ord. No. 187,719, Eff. 1/23/23.) The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as "EV CAPABLE" in accordance with the California Electrical Code.

99.04.106.4.2.5. Electric Vehicle Ready Space Signage. (Added by Ord. No. 187,719, Eff. 1/23/23.) Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s).

99.04.106.5. Cool Roof for Reduction of Heat Island Effect. (Amended by Ord. No. 187,208, Eff. 11/5/21.) Roofing material shall comply with both LAMC Subsections 99.04.106.5.1 and 99.04.106.5.2, or comply with LAMC Subsection 99.04.106.5.3.

EXCEPTIONS:

  1. Roof repair as defined in Section 100.1(b) of the California Energy Code; or

  2. Roof replacement when the roof area being replaced is equal to or less than 50% of the total roof area; or

  3. Roof replacement where solar systems are being installed; or

  4. Additions resulting in less than 500 square feet of added roof area or less than 50% of the total roof area, whichever is greater; or

  5. Roof construction that has a thermal mass over the roof membrane, including areas of vegetated (green) roofs, weighing at least 25 pounds per square foot.

99.04.106.5.1. Solar Reflectance. Roofing material shall have a minimum three- year aged solar reflectance equal to or greater than the values specified in LAMC Tables 99.04.106.5.1 and 99.04.106.5.2. Solar reflectance shall be determined by testing by an approved agency in accordance with ASTM C1549, ASTM E1918 or CRRC-1. Solar reflectance values shall be based on the aged reflectance value of the roofing product or the equation in California Green Building Standards Code (CALGreen) Section A4.106.5.1 if aged solar reflectance values are not available. (Amended by Ord. No. 187,208, Eff. 11/5/21.)

99.04.106.5.2. Thermal Emittance. Roofing materials shall have an emittance value equal to or greater than those specified in LAMC Tables 99.04.106.5.1 and 99.04.106.5.2. Thermal emittance shall be determined by testing by an approved agency in accordance with ASTM C1371, ASTM E408 or CRRC-1. (Amended by Ord. No. 187,208, Eff. 11/5/21.)

99.04.106.5.3. Solar Reflectance Index. Roofing materials shall have a three- year aged Solar Reflectance Index equal to or greater than those specified in LAMC Tables 99.04.106.5.1 and 99.04.106.5.2. Aged Solar Reflectance Index (SRI) may be calculated using the SRI Calculation Worksheet (SRI-WS) developed by the California Energy Commission or in compliance with ASTM E1980-01 as specified in the 2019 California Energy Code. Solar reflectance values used in the SRI-WS shall be based on the aged reflectance value of the roofing product. Certified thermal emittance used in the SRI-WS may be either the initial value or the aged value listed by the Cool Roof Rating Council. (Amended by Ord. No. 187,208, Eff. 11/ 5/21.)

a Energy Commission or in compliance with ASTM E1980-01 as specified in the 2019 California Energy Code. Solar reflectance values used in the SRI-WS shall be based on the aged reflectance value of the roofing product. Certified thermal emittance used in the SRI-WS may be either the initial value or the aged value listed by the Cool Roof Rating Council. (Amended by Ord. No. 187,208, Eff. 11/ 5/21.)

TABLE TABLE 99.04.106.5.1 [LOW-RISE] (Added by Ord. No. 187,208, Eff. 11/5/21.)

ROOF SLOPE MINIMUM 3-YEAR AGED SOLAR THERMAL EMITTANCE 3 YEAR AGED SOLAR REFLECTANCE REFLECTANCE INDEX (SRI) ≤ 2:12 0.65 0.85 78

2:12 0.25 0.85 20

TABLE 99.04.106.5.2 [HIGH-RISE] (Added by Ord. No. 187,208, Eff. 11/5/21.)

ROOF SLOPE MINIMUM 3-YEAR AGED SOLAR THERMAL EMITTANCE 3 YEAR AGED SOLAR REFLECTANCE REFLECTANCE INDEX (SRI) ≤ 2:12 0.65 0.75 78

2:12 0.25 0.75 20

99.04.106.7. Reduction of Heat Island Effect for Nonroof Areas [N]. Reduce nonroof heat islands for 50% of pathways patios, driveways or other paved areas by using one or more of the methods listed.

  1. Use trees or other plantings to provide shade and that mature within 15 years of planting. Trees shall be suitable in mature size and environmental requirements for the site. Tree selection and placement shall consider location and size of areas to be shaded, location of utilities, views from the structure, distance to sidewalks and foundations, overhangs onto adjacent properties and streets; other infrastructure and adjacent to landscaping. In addition, shading shall not cast a shadow, as specified, on any neighboring solar collectors pursuant to California Public Resources Code Section 25981, et seq. (Solar Shade Control Act);

  2. Use high albedo materials with an initial solar reflectance value of at least .30 as determined in accordance with American Society for Testing and Materials (ASTM) Standards E1918 or C1549;

  3. Use open grid pavement system or pervious or permeable pavement system;

  4. Use solar panel arrays to create a canopy shade system; or

  5. Other methods of reducing heat island effects acceptable to the Department.

99.04.106.8. All-Electric Buildings. (Added by Ord. No. 187,714, Eff. 1/23/23.) All newly constructed buildings shall be all-electric buildings.

EXCEPTIONS:

  1. Application for a building permit is submitted, accepted by the Department of Building and Safety, and building permit application fees are paid prior to April 1, 2023.

  2. Application for a building permit for an Affordable Housing Project, as defined in the Mayor's Executive Directive 1.3, is submitted, accepted by the Department of Building and Safety, and building permit application fees are paid prior to June 1, 2023.

  3. Attached accessory dwelling units using existing gas piping systems in conjunction with the primary dwelling.

  4. Cooking equipment contained within kitchens located in a public use area, as defined in the California Building Code Chapter 2, such as restaurants, commissaries, cafeterias, and community kitchens provided the electrical infrastructure is installed in accordance with Section 99.04.106.8.1.

  5. Gas-powered emergency life-safety systems, including emergency backup.

99.04.106.8.1. Requirements for Combustion Equipment. (Added by Ord. No. 187,714, Eff. 1/23/23.) Where required by Section 99.04.106.8, the electrical infrastructure shall be installed to accommodate the future installation of an electrical heating or cooking appliance/equipment in the following ways:

  1. Branch circuit wiring, electrically isolated and designed to serve all electrical heating and cooking appliances in accordance with manufacturer requirements and the California Electrical Code, including the appropriate voltage, phase, minimum amperage, and an electrical receptacle or junction box within 5 feet of the appliance that is accessible with no obstructions. Appropriately sized conduit may be installed in lieu of conductors; and

  2. Labeling of both ends of the unused conductors or conduit shall be with "For Future Electrical Appliance/Equipment"; and

  3. Reserved circuit breakers in the electrical panel for each branch circuit, appropriately labeled (e.g., "Reserved for Future Electric Range/ Equipment"), and positioned on the opposite end of the panel supply conductor connection; and

  4. Connected subpanels, panelboards, switchboards, busbars, and transformers shall be sized to serve the future electrical heating appliances and equipment. The electrical capacity requirements shall be adjusted for demand factors in accordance with the California Electric Code.

ENERGY EFFICIENCY

SEC. 99.04.201. GENERAL.

Esta sección aún no está traducida y se muestra en inglés.

99.04.201.1. Scope. (Amended by Ord. No. 185,587, Eff. 7/16/18.) The provisions of this division shall establish means of conserving energy.

SEC. 99.04.211. RENEWABLE ENERGY.

Esta sección aún no está traducida y se muestra en inglés.

(Amended by Ord. No. 184,692, Eff. 12/30/16.)

99.04.211.4. Solar Ready Buildings. Buildings shall comply with the following:

  1. All one- and two-family dwellings shall comply with Sections 110.10 (b)1A, 110.10(b)2, 110.10(b)3, 110.10(b)4, 110.10(c), 110.10(d) and 110.10(e) of the California Energy Code (CCR, Title 24, Part 6).

  2. All buildings, other than one- and two-family dwellings, shall comply with Sections 110.10(b) through 110.10(d) of the California Energy Code (CCR, Title 24, Part 6).

EXCEPTIONS:

  1. Additions having less than 2,000 sq. ft. of new roof area.

  2. Alterations.

SEC. 99.04.303. INDOOR WATER USE.

Esta sección aún no está traducida y se muestra en inglés.

(Amended by Ord. No. 187,719, Eff. 1/23/23.)

99.04.303.4. Water Use Reduction. (Added by Ord. No. 184,246, Eff. 6/6/16.) A 20 percent reduction in the overall use of potable water within the building shall be provided. The reduction shall be based on the maximum allowable water use per plumbing fixture and fittings as required by the Los Angeles Building Standards. The 20 percent reduction in potable water use shall be demonstrated by the following method:

99.04.303.4.1. Performance Method. A calculation demonstrating a 20% reduction in the building "water use baseline", as established in LAMC Table 99.04.303.4.1, shall be provided.

EXCEPTIONS:

  1. Projects with plumbing fixtures and fittings that comply with the maximum flow rate values in LAMC Table 99.04.303.4.2.

  2. Additions and alterations to buildings where the new fixtures and

fittings comply with the maximum flow rate values in LAMC Table 99.04.303.4.2.

  1. Buildings utilizing recycled water in accordance with LAMC Subsection 99.04.305.2.

  2. Replacement of plumbing fixtures and fittings.

TABLE 99.04.303.4.1 WATER USE BASELINE 3

FIXTURE TYPE BASELINE FLOW RATE DURATION DAILY USES OCCUPANTS 2 Showerheads 1.8 gpm @ 80 psi 8 min. 1 X 2a Lavatory Faucets, 1.2 gpm @ 60 psi .25 min. 3 X Residential Lavatory Faucets, Common/ 0.5 gpm @ 60 psi .25 min. 3 X Public Uses Kitchen Faucets 1.8 gpm @ 60 psi 4 min. 1 X 2b Metering Faucets 0.20 gallons/cycle 3 X Water Closets 1.28 gallons/flush 1 flush 1 male 1 X 3 female Urinals 0.125 gallons/flush 1 flush 2 male X

Fixture "Water Use" = Flow rate X Duration X Occupants X Daily uses

  1. The daily use number shall be increased to three if urinals are not installed in the room.
  2. Refer to Table A, Chapter 4 of the California Plumbing Code, for occupant load factors. a. Shower use by occupants depends on the type of use of a building or portion of a building. For example, the total occupant load for a health club, but only a fraction of the occupants in an office building as determined by the anticipated number of users. b. Kitchen faucet use is determined by the occupant load of the area served by the fixture.
  3. Use Worksheet WS-1 of the 2016 CALGreen Code to calculate baseline water.

TABLE 99.04.303.4.2 WATER REDUCTION FIXTURE FLOW RATES

FIXTURE TYPE MAXIMUM ALLOWABLE FLOW RATE Kitchen Faucets* 1.5 gpm @ 60 psi Clothes Washers ENERGY-STAR certified Dishwashers ENERGY-STAR certified

*Kitchen faucets may temporarily increase the flow to 2.2 gpm at 60 psi, and must default to 1.5 gpm at 60 psi. This requirement does not apply to a faucet in commercial kitchens or in buildings that have water closets with a maximum flush rate of 1.06 gpf installed throughout.

SEC. 99.04.304. OUTDOOR WATER USE.

Esta sección aún no está traducida y se muestra en inglés.

(Amended by Ord. No. 186,488, Eff. 12/27/19.)

99.04.304.3. Metering Outdoor Water Use. A landscape water meter provided by the City of Los Angeles Department of Water and Power shall be installed for landscape irrigation for the following:

  1. New construction projects, as defined by the California Department of Water Resources Model Water Efficient Landscape Ordinance, with aggregate landscape area over 500 square feet.

  2. When required by the California Department of Water Resources Model Water Efficient Landscape Ordinance.

  3. Additions and alterations, with a valuation of $200,000 or more, where the entire potable water system is replaced, including all underground piping to the existing meter.

99.04.304.4. Exterior Faucets. Locks shall be installed on all publicly accessible exterior faucets and hose bibs.

EXCEPTION: Single family dwellings.

99.04.304.5. Swimming Pool Covers. For one- and two-family dwellings, any permanently installed outdoor in-ground swimming pool or spa shall be equipped with a cover having a manual or power-operated reel system. For irregular- shaped pools where it is infeasible to cover 100 percent of the pool due to its irregular shape, a minimum of 80 percent of the pool shall be covered.

EXCEPTION: Additions or alterations to existing swimming pools and spas with a building valuation not exceeding $25,000.

Note: Safety pool covers installed pursuant to the exception to LAMC Subsection 91.3109.4 shall meet the requirements of ASTM F 1346. (Amended by Ord. No. 185,587, Eff. 7/16/18.)

SEC. 99.04.305. WATER REUSE SYSTEMS.

Esta sección aún no está traducida y se muestra en inglés.

(Added by Ord. No. 184,246, Eff. 6/6/16.)

99.04.305.1. Recycled Water Supply to Fixtures. (Amended by Ord. No. 186,488, Eff. 12/27/19.) When City-recycled water is available for use within 200 feet of the property line, 100 percent of water for water closets, urinals, floor drains, and process cooling and heating in that building shall come from City- recycled water. Recycled water systems shall be designed and installed in accordance with the Los Angeles Plumbing Code.

EXCEPTIONS:

  1. Additions that use any part of the existing plumbing system.

  2. Alterations that do not include replacing all of the potable water piping.

  3. Where City-recycled water quality has been deemed non-suitable for a particular fixture or equipment, connection to the City is not required. The fixture and/or equipment shall be dual-plumbed to allow for future connection.

99.04.305.2. Graywater Ready. (Amended by Ord. No. 186,488, Eff. 12/27/19.) Waste piping shall be arranged to permit the discharge from the clothes washer, bathtub, showers and bathroom/restroom washbasins to be used for a future graywater irrigation system(s). The flow from the fixtures shall be piped separately, and, at a minimum, be adequate to supply the irrigation demand as determined by the California Department of Water Resources' Model Water Efficiency Landscape Ordinance (MWELO). The point(s) of connection between graywater piping and other waste piping shall be accessible (as defined in LAMC 99.02.202) and provided with signage that is satisfactory to the Department.

EXCEPTIONS:

  1. Buildings with a graywater, rainwater harvesting, or other water reuse system.

  2. Sites with landscape areas not exceeding 500 square feet.

  3. Projects where graywater systems are not permitted due to geological conditions.

  4. Additions and alterations that use the existing building drain.

99.04.305.3. Cooling Towers [N]. (Amended by Ord. No. 185,587, Eff. 7/16/18.) Cooling towers shall comply with LAMC Subdivision 99.04.305.3.1 or 99.04.305.3.2.

99.04.305.3.1. Buildings 25 Stories or Less. Buildings of 25 stories or less shall comply with one of the following:

  1. Cooling towers shall have a minimum of 6 cycles of concentration (blowdown); or

  2. A minimum of 50 percent of makeup water supply to cooling towers shall come from non-potable water sources, including treated backwash.

99.04.305.3.2. Buildings Over 25 Stories. Buildings over 25 stories shall comply with all of the following:

  1. Cooling towers shall have a minimum of 6 cycles of concentration (blowdown); and

  2. 100 percent of makeup water supply to cooling towers shall come from non-potable water sources, including treated backwash.

EXCEPTION: Where the amount of graywater produced by the plumbing system is insufficient to meet the total makeup water demand, as determined by the Department, potable water can be used to compensate for the deficiency.

99.04.305.4. Groundwater Discharge [N]. Where groundwater is being extracted and discharged, a system for onsite reuse of the groundwater shall be developed and constructed. Alternatively, the groundwater may be discharged to the sewer.

SEC. 99.04.407. WATER RESISTANCE AND MOISTURE MANAGEMENT.

Esta sección aún no está traducida y se muestra en inglés.

99.04.407.3. Flashing Details. Provide flashing details on the building plans which comply with accepted industry standards or manufacturer’s instructions at the following locations:

  1. Around windows and doors;

  2. Roof valleys;

  3. Chimneys to roof intersections.

99.04.407.4. Material Protection. Protect building materials delivered to the construction site from rain and other sources of moisture.

SEC. 99.04.408. CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING.

Esta sección aún no está traducida y se muestra en inglés.

(Amended by Ord. No. 184,692, Eff. 12/30/16.)

99.04.408.1. Construction Waste Management. Comply with LAMC Section 66.32, et seq., of the Los Angeles Municipal Code.

SEC. 99.04.504. POLLUTANT CONTROL

Esta sección aún no está traducida y se muestra en inglés.

(Amended by Ord. No. 186,486, Eff. 1/28/20.)

99.04.504.6. Filters. (Amended by Ord. No. 187,719, Eff. 1/23/23.) Mechanically ventilated buildings shall meet the air filtration requirements of the California Energy Code.

Tables 4.504.1, 4.504.2, and 4.504.3 of the California Green Building Standards Code, Title 24, Part 11 are not adopted. The following tables shall apply instead:

TABLE 4.504.1 ADHESIVE VOC LIMIT 1, 2 Less Water and Less Exempt Compounds in Grams per Liter

ARCHITECTURAL APPLICATIONS VOC LIMIT Indoor carpet adhesives 50 Carpet pad adhesives 50 Outdoor carpet adhesives 150 Wood flooring adhesives 100 Rubber floor adhesives 60 Subfloor adhesives 50 Ceramic tile adhesives 65 VCT and asphalt tile adhesives 50 Drywall and panel adhesives 50 Cove base adhesives 50 Multipurpose construction adhesives 70 Structural glazing adhesives 100 Single-ply roof membrane adhesives 250 Other adhesives not specifically listed 250 SPECIALTY APPLICATIONS PVC welding 510 CPVC welding 490 ABS welding 325 Plastic cement welding 100 Adhesive primer for plastic 550 Contact adhesive 80 Special purpose contact adhesive 250 Structural wood member adhesive 140 Top and trim adhesive 540 SUBSTRATE SPECIFIC APPLICATIONS Metal to metal 30 Plastic foams 50 Porous material (except wood) 50 Wood 30 Fiberglass 80

  1. If an adhesive is used to bond dissimilar substrates together, the adhesive with the highest VOC content shall be allowed.
  2. For additional information regarding methods to measure the VOC content specified in this table, see South Coast Air Quality Management District Rule

TABLE 4.504.2 SEALANT VOC LIMIT Less Water and Less Exempt Compounds in Grams per Liter

SEALANTS VOC LIMIT Architectural 50 Marine deck 760 Non-membrane roof 300 Roadway 250 Single-ply roof membrane 450 Other 420 SEALANT PRIMERS Architectural Nonporous 250 Porous 775 Modified bituminous 500 Marine deck 760 Other 750

TABLE 4.504.3 VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS 2, 3 Grams of VOC per Liter of Coating Less Water and Less Exempt Compounds

COATING CATEGORY VOC LIMIT Flat coatings 50 Nonflat coatings 50 Nonflat-high gloss coatings 50 SPECIALTY COATINGS Aluminum roof coatings 100 Basement specialty coatings 400 Bituminous roof coatings 50 Bituminous roof primers 350 Bond breakers 350 Concrete curing compounds 100 Concrete curing compounds, Roadways & Bridges 350 Concrete/masonry sealers 100 Driveway sealers 50 Dry fog coatings 50 Faux finishing coatings Clear Top Coat 100 Decorative Coatings 350 Glazes 350 Japan 350 Trowel Applied Coatings 50 Fire resistive coatings 150 Floor coatings 50 Form-release compounds 100 Graphic arts coatings (sign paints) 200 High temperature coatings 420 Industrial maintenance coatings 100 Low solids coatings 1 120 Magnesite cement coatings 450 Mastic texture coatings 100 Metallic pigmented coatings 150 Multicolor coatings 250 Pretreatment wash primers 420 Primers, sealers, and undercoaters 100 Reactive penetrating sealers 350 Recycled coatings 250 Roof coatings 50 Roof coatings, aluminum 100 Rust preventative coatings 100 Shellacs Clear 730 Opaque 550 Specialty primers, sealers and undercoaters 100 Stains 100 Stains, Interior 250 Stone consolidants 450 Swimming pool coatings 340 Traffic marking coatings 100 Tub and tile refinish coatings 420 Waterproofing membranes 100 Wood coatings 275 Wood preservatives 350 Zinc-rich primers 100

  1. Grams of VOC per liter of coating, including water and including exempt compounds.
  2. The specified limits remain in effect unless revised limits are listed in subsequent columns in the table.
  3. Values in this table are derived from those specified by the South Coast Air Management District (SCAQMD) Rule 1113. More information is available from the SCAQMD.

DIVISION 5 NONRESIDENTIAL MANDATORY MEASURES

(Amended by Ord. No. 184,692, Eff. 12/30/16.)

99.05.100 Basic Provisions. 99.05.106 Site Development.

Energy Efficiency

99.05.201 General. 99.05.211 Renewable Energy. 99.05.303 Indoor Water Use. 99.05.304 Outdoor Water Use. 99.05.305 Water Reuse Systems. 99.05.408 Construction Waste Reduction, Disposal and Recycling. 99.05.504

GoCodebook ofrece acceso público limitado, búsqueda, citas, explicación multilingüe e interpretación práctica de normas de construcción legalmente adoptadas. No sustituye a las publicaciones oficiales del ICC ni de los códigos de California.