San Francisco requires a Flexible Retail space to keep two Uses running at the same time. The building code counts people by what each part of the floor is used for, so the floor split, not the tenancy, is what spends the single-exit budget.

Ask AI about this article Free to try — answers cite the code section they came from.
Sunwoo Kim
AI-assisted article · General information, not legal advice ·details

Researched and written with AI tools. Property examples are illustrative analyses based on public records, and people described may be composites.

In San Francisco, a Flexible Retail Use is one Planning entitlement whose continuing condition is that the space keep at least two Uses running at once. The California Building Code prices that condition at the exit door: the occupant load factor follows the function of the space, each function's area is counted independently, and exits follow the aggregate occupant load served. Table 1006.3.4(2) permits a single first-story exit to 49 occupants for A, B, E, F, M and U alike: the ceiling does not move across those six groups, and the count under it arrives far sooner at 15 net than at 150 gross.

Key numbers

Figure What it governs Section
150 gross Business areas Table 1004.5
60 gross Mercantile Table 1004.5
15 net Assembly unconcentrated Table 1004.5
2 exits Occupant load 1 to 500 per story Table 1006.3.3
49 One first-story exit: A, B, E, F, M, U Table 1006.3.4(2)
29 One second-story exit: B, F, M, S Table 1006.3.4(2)
NP One exit, third story and higher Table 1006.3.4(2)
50 or more Occupant load posted, listed rooms Section 1004.9

Two Uses at any given time

San Francisco Planning Code Section 202.9 supplies the premise, under the subdivision heading "Minimum of two Uses":

A Flexible Retail Use must operate with at least two Uses at any given time.

The same section says the entitlement "incorporates two or more specific uses", each "Principally Permitted in the underlying zoning district". Section 202.9 takes its definition from Section 102, and says nothing about occupant load or exits. It makes two simultaneous activities a condition of the entitlement rather than a tenant's incidental choice.

The factor follows the function of the space

California Building Code Section 1004.5 divides the floor area by "the occupant load factor assigned to the function of the space as set forth in Table 1004.5" — the function, not the Planning Use and not the tenant's trade name.

Table 1004.5 holds the spread: "Business areas | 150 gross", Mercantile at 60 gross, and, under "Assembly without fixed seats", "Unconcentrated (tables and chairs) | 15 net" — a tenfold move in the divisor.

California Building Code Section 1004.3 splits the floor: an area containing "multiple functions having different occupant load factors" takes a design occupant load "based on the floor area of each function calculated independently".

Which story the space sits on

California Building Code Section 1006.3 rejoins them: spaces on a story reach the required exits "based on the aggregate occupant load served in accordance with this section". California Building Code Section 1006.3.3 sets the default from Table 1006.3.3, two exits at 1 to 500 occupants per story, and points to Section 1006.3.4 for the single-exit relief.

California Building Code Section 1006.3.4 allows one exit "where one of the following conditions exists", the first being that the occupant load and travel distance "do not exceed the values in Table 1006.3.4(1) or 1006.3.4(2)". That table's first-story row reads "A, B b, E, F b, M, U | 49 | 75", the trailing letters being footnote markers. Footnote b gives Group B, F and S occupancies in sprinklered buildings a "maximum exit access travel distance of 100 feet".

When the two functions are separate occupancies

California Building Code Section 1004.4 turns on occupancies rather than functions: where "two or more occupancies utilize portions of the same means of egress system", those components "shall meet the more stringent requirements of all occupancies that are served". Whether two Planning Uses map to two functions, or to two occupancy classifications, is a determination this article does not make. The chain above needs neither.

Where the cheaper lane is, and what it costs

California Building Code Section 1004.5 carries its own Exception, "Where approved by the building official, the actual number of occupants for whom each occupied space, floor or building is designed, although less than those determined by calculation, shall be permitted to be used in the determination of the design occupant load", and read together with Section 1004.9 the price sits in the same paragraph: a room "used for assembly, classroom, dining, drinking or similar purposes" at "an occupant load of 50 or more" has that number "posted in a conspicuous place, near the main exit", on signs "maintained by the owner or the owner's authorized agent". The lower number becomes a limit recorded on the wall; this article applies neither condition.

What this looks like on the drawing

Two lines carry it. The demising line fixes how the floor divides between the two Uses the entitlement obliges the space to keep running, and Section 1004.3 counts each side on its own factor. Move that line and the aggregate occupant load moves with it, which is why a line that reads as a tenancy decision decides whether a second exit is drawn.

Currency

San Francisco Planning Code Section 202.9 was added by Ordinance 285-18 (effective January 7, 2019) and amended by Ordinance 136-21 (effective September 4, 2021) and Ordinance 249-23 (effective January 14, 2024), which added the Abandonment division. That is more than 24 months before September 2026, so nothing quoted here was amended inside that window. The library page carries the Planning Code's 2026-08 edition, updated 2026-09-23.

The building-code pages carry the 2025 California Building Code (Title 24, Part 2), 2025 edition, updated in the library on October 24, 2026, and print no per-section amendment history and no effective date — so no amendment date was established for any building-code section or table quoted above. That is a gap in the record, not a finding that they are unamended. Confirm the version in force before relying on a figure here.

Frequently asked questions

Does assembly carry a stricter single-exit threshold than business?

No. Table 1006.3.4(2) puts A, B, E, F, M and U on one first-story row, at 49 occupants and 75 feet, so the ceiling is identical across those six groups. What differs is the divisor in Table 1004.5: 150 gross for Business areas, 15 net for "Unconcentrated (tables and chairs)".

Is the occupant load posted in every space?

Section 1004.9 reaches "Every room or space which is used for assembly, classroom, dining, drinking or similar purposes having an occupant load of 50 or more". That clause closes on "or similar purposes", so the occupant load alone does not settle whether a space sits inside it.

What happens if only one Use runs?

Under its Abandonment heading, Section 202.9 writes the consequence: a Flexible Retail Use operating only one Use for 90 days or more "shall be deemed abandoned, and no new Flexible Retail Use shall be restored without the issuance of a new building permit". On a good faith showing, "the Zoning Administrator may grant a 90-day extension."